UPS-25KVA
RD
Pallet
China
85044019
UPS Technical parameters | |||
| input | item | 50K-300K Input & output both are tri-phase | 1K-30K Input & output both are single-phase |
| voltage | 380V±20% | 220V±20% | |
| frequency | 50Hz/60Hz±10% | ||
| Effiency | ≥95% | ||
| output | Voltage adjustment | 380V±1% | 220V±0.5% |
| Harmonic distortion | Linear load <3% Non-linear load<5% | ||
| Unbalance voltage | Load balancing<=1%,unbalanced load<=3% | 0 | |
| Phase movement angle | Load balancing<=1°,unbalanced load<=3° | 0 | |
| Dynamic transient | Recovery time<=10ms | Recovery time<=10ms | |
| Overload | 110%≥300Min 125%≥10Min 150%≥1Min | ||
| Waveform | pure sine waveform | ||
| Switching time | 0s | ||
| battery | type | Ssaled lead-acid maintenance-free/colloid | |
| manage function | Smart battery management system | ||
| charging time | Fully charged after 12 hours to 90% | Fully charged after 8 hours to 90% | |
| protection | battery | Battery low energy automatic shutdown,no fuse switch protection | |
| over load | Automatically jump to 30 seconds after the overload bypass,automatic recovery | ||
| over temperature | Internal temperature>85ºC,and automatically jump to bypass | ||
| output short-circuit | Current limiting,automatic shutdown,fuse and no fuse switch protection | ||
| UPS abnormal | Automatically jump to bypass the municipal electricity supply | ||
| filter | 10-10KHz at 40db;100KHz-100MHz ar 70db | ||
| batter low voltage | LED lights up when the low battery voltage | ||
| environment | temperature | -10ºC- 50ºC | |
| Relative humidity | 0-93% no dew | ||
| Operation condition | sea level <=3000m | ||
| Number of phases | Model | Rated capacity (KVA) | Rated load (KW) | Weight(KG) | Size W*D*H(mm) |
| single phase | UPS-1KVA | 1 | 0.8 | 56 | 200*530*600 |
| UPS-2KVA | 2 | 1.6 | 78 | 200*600*632 | |
| UPS-3KVA | 3 | 2.4 | 80 | 200*600*632 | |
| UPS-4KVA | 4 | 3.2 | 85 | 220*580*540 | |
| UPS-6KVA | 6 | 4.8 | 89 | 220*580*540 | |
| UPS-8KVA | 8 | 6.4 | 118 | 220*580*700 | |
| UPS-10KVA | 10 | 8 | 130 | 300*590*870 | |
| UPS-12KVA | 12 | 9.6 | 140 | 300*590*870 | |
| UPS-15KVA | 15 | 12 | 175 | 410*670*935 | |
| UPS-20KVA | 20 | 16 | 250 | 730*700*1180 | |
| UPS-25KVA | 25 | 20 | 260 | 730*700*1180 | |
| UPS-30KVA | 30 | 24 | 275 | 730*700*1180 | |
| Three phase | UPS-50KVA | 50 | 40 | 530 | 800*740*1400 |
| UPS-60KVA | 60 | 48 | 550 | 800*740*1400 | |
| UPS-80KVA | 80 | 64 | 600 | 800*740*1400 | |
| UPS-100KVA | 100 | 80 | 650 | 1070*740*1400 | |
| UPS-120KVA | 120 | 96 | 750 | 1070*740*1400 | |
| UPS-160KVA | 160 | 128 | 1800 | 1770*750*1800 | |
| UPS-200KVA | 200 | 160 | 1900 | 1770*750*1800 |
UPS Technical parameters | |||
| input | item | 50K-300K Input & output both are tri-phase | 1K-30K Input & output both are single-phase |
| voltage | 380V±20% | 220V±20% | |
| frequency | 50Hz/60Hz±10% | ||
| Effiency | ≥95% | ||
| output | Voltage adjustment | 380V±1% | 220V±0.5% |
| Harmonic distortion | Linear load <3% Non-linear load<5% | ||
| Unbalance voltage | Load balancing<=1%,unbalanced load<=3% | 0 | |
| Phase movement angle | Load balancing<=1°,unbalanced load<=3° | 0 | |
| Dynamic transient | Recovery time<=10ms | Recovery time<=10ms | |
| Overload | 110%≥300Min 125%≥10Min 150%≥1Min | ||
| Waveform | pure sine waveform | ||
| Switching time | 0s | ||
| battery | type | Ssaled lead-acid maintenance-free/colloid | |
| manage function | Smart battery management system | ||
| charging time | Fully charged after 12 hours to 90% | Fully charged after 8 hours to 90% | |
| protection | battery | Battery low energy automatic shutdown,no fuse switch protection | |
| over load | Automatically jump to 30 seconds after the overload bypass,automatic recovery | ||
| over temperature | Internal temperature>85ºC,and automatically jump to bypass | ||
| output short-circuit | Current limiting,automatic shutdown,fuse and no fuse switch protection | ||
| UPS abnormal | Automatically jump to bypass the municipal electricity supply | ||
| filter | 10-10KHz at 40db;100KHz-100MHz ar 70db | ||
| batter low voltage | LED lights up when the low battery voltage | ||
| environment | temperature | -10ºC- 50ºC | |
| Relative humidity | 0-93% no dew | ||
| Operation condition | sea level <=3000m | ||
| Number of phases | Model | Rated capacity (KVA) | Rated load (KW) | Weight(KG) | Size W*D*H(mm) |
| single phase | UPS-1KVA | 1 | 0.8 | 56 | 200*530*600 |
| UPS-2KVA | 2 | 1.6 | 78 | 200*600*632 | |
| UPS-3KVA | 3 | 2.4 | 80 | 200*600*632 | |
| UPS-4KVA | 4 | 3.2 | 85 | 220*580*540 | |
| UPS-6KVA | 6 | 4.8 | 89 | 220*580*540 | |
| UPS-8KVA | 8 | 6.4 | 118 | 220*580*700 | |
| UPS-10KVA | 10 | 8 | 130 | 300*590*870 | |
| UPS-12KVA | 12 | 9.6 | 140 | 300*590*870 | |
| UPS-15KVA | 15 | 12 | 175 | 410*670*935 | |
| UPS-20KVA | 20 | 16 | 250 | 730*700*1180 | |
| UPS-25KVA | 25 | 20 | 260 | 730*700*1180 | |
| UPS-30KVA | 30 | 24 | 275 | 730*700*1180 | |
| Three phase | UPS-50KVA | 50 | 40 | 530 | 800*740*1400 |
| UPS-60KVA | 60 | 48 | 550 | 800*740*1400 | |
| UPS-80KVA | 80 | 64 | 600 | 800*740*1400 | |
| UPS-100KVA | 100 | 80 | 650 | 1070*740*1400 | |
| UPS-120KVA | 120 | 96 | 750 | 1070*740*1400 | |
| UPS-160KVA | 160 | 128 | 1800 | 1770*750*1800 | |
| UPS-200KVA | 200 | 160 | 1900 | 1770*750*1800 |